Prosthetisation of a K2 Patient with Sub-ischial Socket Compared to Ischial Containment (IC) Socket: A Case Report

https://doi.org/10.36082/jpost.v4i1.2103

Authors

  • Davide Buratti Università degli studi di Milano
  • Matteo Vaccari TCIO (Department of research, Faculty of Osteopathy, Milan)

Keywords:

Artificial lower limb, Ischial containment socket, Prosthetic socket, Transfemoral amputation, Sub-ischial socket

Abstract

Background: Ischial Containment Socket (ICS) has been the standard treatment for transfemoral amputees for thirty years, but the high edges and the ischial containment contribute to the discomfort of the socket especially when the patient is standing and while he is sitting.Aims: The purpose of this study is to compare ICS to sub-ischial socket in a unilateral TFA K2 patient.Methods: Two custom-fabricated sockets, worn full-time for 3 weeks, with testing on day 0 and at 3 weeks after socket delivery. The case report examined a 71-year-old woman three years after one-sided transfemoral amputation to the right leg, with K2 functional level. The protocol used contained three questionnaires, the measurement of the hip range of motion and 2 physical tests.Results: The most relevant results were the reduction of the pelvic inclination during the sitting with a variation of -42.9% (7° with the ICS and 4° with the sub-ischial socket), and an increase in all the measurements of the angles of the hip, especially in abduction and extension with percentage change that reaches +300% each. The two sockets were equivalent in the 2MWT (P-value=0.98) and in the 4SST (P-value=0.88) (statistical significance p<0.05). The patient reported that the sub-ischiatic socket is more comfortable and has more freedom of movement.Conclusion: It can be said that for patient K2 examined, the sub-ischial socket is a valid clinical alternative to the one with ischial containment, since it does not affect aspects such as stability and dynamics, but it also offers improvements in the stump-socket interface.

Downloads

Download data is not yet available.

References

Fatone S, Caldwell R, Angelico J, Stine R, Kim K-Y, Gard S, et al. Comparison of Ischial Containment and Subischial Sockets on Comfort, Function, Quality of Life, and Satisfaction With Device in Persons With Unilateral Transfemoral Amputation: A Randomized Crossover Trial. Archives of physical medicine and rehabilitation. 2021;102(11):2063-73.e2.

Fatone S, Caldwell R. Northwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation: Part 2 Description and Preliminary evaluation. Prosthet Orthot Int. 2017;41(3):246-50.

Fatone S, Dillon M, Stine R, Tillges R. Coronal plane socket stability during gait in persons with transfemoral amputation: Pilot study. J Rehabil Res Dev. 2014;51(8):1217-28.

Caldwell R, Fatone S. Technique modifications for a suction suspension version of the Northwestern University Flexible Sub-Ischial Vacuum socket: The Northwestern University Flexible Sub-Ischial Suction socket. PROSTHET ORTHOT INT. 2019;43(2):233-9.

Dillon MP, Fernandez RGD, Erbas B, Briggs C, Quigley M. Prediction of Skeletal Medial-Lateral for transfemoral ischial containment sockets. J Rehabil Res Dev. 2016;53(2):253-62.

Kahle JT, Highsmith MJ. Transfemoral interfaces with vacuum assisted suspension comparison of gait, balance, and subjective analysis: Ischial containment versus brimless. Gait Posture. 2014;40(2):315-20.

Fatone S, Caldwell R. Northwestern University Flexible Subischial Vacuum Socket for persons with transfemoral amputation-Part 1: Description of technique. Prosthet Orthot Int. 2017;41(3):237-45.

Ware JE, Sherbourne CD. The MOS 36-Item Short-Form Health Survey (SF-36): I. Conceptual Framework and Item Selection. Med Care. 1992;30(6):473-83.

McMurray A, Grant S, Griffiths S, Letford A. Health-related quality of life and health service use following total hip replacement surgery. J Adv Nurs. 2002;40(6):663-72.

Shepperd S, Harwood D, Jenkinson C, Gray A, Vessey M, Morgan P. Randomised controlled trial comparing hospital at home care with inpatient hospital care. I: three month follow up of health outcomes. BMJ. 1998;316(7147):1786-91.

Devlin M, Pauley T, Head K, Garfinkel S. Houghton scale of prosthetic use in people with lower extremity amputations: Reliability, validity, and responsiveness to change. Arch Phys Med Rehabil. 2004;85(8):1339-44.

Miller WC, Deathe AB, Speechley M. Lower extremity prosthetic mobility: A comparison of 3 self report scales. Arch Phys Med Rehabil. 2001;82(10):1432-40.

Legro MW, Reiber GD, Smith DG, del Aguila M, Larsen J, Boone D. Prosthesis evaluation questionnaire for persons with lower limb amputations: Assessing prosthesis-related quality of life. Arch Phys Med Rehabil. 1998;79(8):931-8.

Brooks D, Parsons J, Hunter JP, Devlin M, Walker J. The 2-minute walk test as a measure of functional improvement in persons with lower limb amputation. Arch Phys Med Rehabil. 2001;82(10):1478-83.

Frlan-Vrgoc L, Vrbani? TS-L, Kraguljac D, Kovacevi? M. Functional outcome assessment of lower limb amputees and prosthetic users with a 2-minute walk test. Coll Antropol. 2011;35(4):1215.

Bohannon RWDPTE, Wang Y-COTRLP, Gershon RCP. Two-Minute Walk Test Performance by Adults 18 to 85 Years: Normative Values, Reliability, and Responsiveness. Arch Phys Med Rehabil. 2015;96(3):472-7.

Gouelle A, Highsmith MJ. Instrumented four square step test in adults with transfemoral amputation: Test-retest reliability and discriminant validity between two types of microprocessor knees. Sensors (Basel). 2020;20(17):1-16.

Datta D, Harris I, Heller B, Howitt J, Martin R. Gait, cost and time implications for changing from PTB to ICEX® sockets. Prosthet Orthot Int. 2004;28(2):115-20.

Kapandji IA. Bewegingsleer. Deel II, De onderste extremiteit. Houten : Bohn Stafleu van Loghum; 2009.

Hagberg K, Häggström E, Uden M, Brånemark R. Socket versus bone-anchored trans-femoral prostheses: Hip range of motion and sitting comfort. Prosthet Orthot Int. 2005;29(2):153-63.

Published

2025-12-04

How to Cite

Buratti, D., & Vaccari, M. . (2025). Prosthetisation of a K2 Patient with Sub-ischial Socket Compared to Ischial Containment (IC) Socket: A Case Report . Journal of Prosthetics Orthotics and Science Technology, 4(1), 1–10. https://doi.org/10.36082/jpost.v4i1.2103